中国质量新闻网
您当前位置: 新闻中心>>《中国国境卫生检疫杂志》>>

采血室空气实时消毒灭菌的效果分析

2012-04-27 15:26:22 中国质量新闻网

    苏水宽,李庶甘,杨坤宇,张毅,郭美华,郑燕平

    厦门国际旅行卫生保健中心,福建 厦门 361012

    摘要:目的 了解实时消毒灭菌方法在国际旅行卫生保健中心采血室的应用效果。方法利用臭氧(O3)消毒机对采血室进行消毒灭菌后再采样进行检测。每次实验时采集3组不同的空气样本进行比较:1组为工作时间内未消毒灭菌的空气样本,2组为工作时间内实时消毒灭菌后的空气样本,3组为休息时间内消毒灭菌后的空气样本。采样时每个房间放置3个细菌计数培养皿,每次采9份标本。对样本进行培养并进行菌落计数。结果连续采集12周的标本,检测结果表明经过消毒灭菌后的采血室空气细菌菌落数为105~314 cfu/m3,空气质量合格。结论可以利用臭氧消毒机对采血室进行实时消毒灭菌。

    关键词:采血室;空气质量;消毒灭菌;臭氧消毒机;效果

    中图分类号:R187.1 文献标识码:B

    Investigation of real time air disinfectionin blood collection room

    SU Shui-kuan, LI Shu-gan, YANG Kun-yu, ZHANGYi, GUO Mei-hua,ZHENG Yan-ping

    Xiamen International Travel HealthcareCenter, Xiamen, Fujian 361012,China

    Abstract:   Objective  To investigate the effection of real time air disinfection in bloodcollection room of International Travel HealthcareCenter.   Methods   Air samples were collectedand tested in the blood collection room was disinfected by ozone(O3) disinfection machine. Three kinds of air samples werecollected in one experiment: the samples from the blood collectionroom without disinfection in the working time, the samples from theblood collection room with disinfection in the working time, andthe samples from the blood collection room with disinfection in therest time. Each time 3 plates of culture count were put diagonallyat equal distance in the room and 9 samples were collected. Thesamples were cultured and the colonies were counted.  Results   A total of 12 weeks` samples were collectedcontinuously, the tests showed that the  colonies were1054-314cfu/m3, it proved that the air condition was qualifiedafter disinfection.  Conclusion   The ozonedisinfection machine can be used to disinfect air condition ofblood collection room in real time.

    Key words:   Blood collection room;Quality of air condition; Disinfection; Ozone (O3) disinfectionmachine; Effectieness

    《中国国境卫生检疫杂志》

(责任编辑:)
最新评论
声明:

本网注明“来源:中国质量新闻网”的所有作品,版权均属于中国质量新闻网,未经本网授权不得转载、摘编或利用其他方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:中国质量新闻网”。违反上述声明者,本网将追究其相关法律责任。若需转载本网稿件,请致电:010-84648459。

本网注明“来源:XXX(非中国质量新闻网)”的作品,均转载自其他媒体,转载目的在于传递更多信息,不代表本网观点。文章内容仅供参考。如因作品内容、版权和其他问题需要同本网联系的,请直接点击《新闻稿件修改申请表》表格填写修改内容(所有选项均为必填),然后发邮件至 lxwm@cqn.com.cn,以便本网尽快处理。

图片新闻
  • 机油液位上升、加注口变“奶盖”不要 ...

  • 安全的召回与召回的安全

  • 广汽本田2019年超额完成目标,体 ...

  • 自研自造铸市场底力 威马为新势力唯 ...

  • 中国汽车文化的先驱 奥迪第三次华丽 ...

最新新闻